This time the scheme, which lcd monitors came to the workshop brand BenQ Q5 × 3 series with a flame monitor complaints minute ago live longer, live and die again switched so onwards. This lcd monitor in around 2003.
if there are search scheme. Our first view all components whether there is a visible broken Elko, apparently all fine components. then forwarded by checking all voltages. sometimes there was tension at times missing. then we take off all the expenses Apparently suply result is the same. stresses emerge and disappear, it means damage to the power supply. we check all components ranging from power supply resistors, Elko, diodes, ceramic capacitors and transistors. but our results did not find the faulty component. last I checked IC602 (pc123) apparently there is little leakage at component. we replace these components with the same series, then I check the voltage was already ok. then we balikin we'd all load pull. and switch scheme monitors.